Electronic Stepper
P/N ESLI

For:
Armor, Curtis, General, Haughton, Otis, Payne, Seaburg, Turnbull, Westinghouse and other steppers.

Features:
• All wiring is done via pluggable terminals
• Onboard Position Indicator for viewing floor position
• Battery back floor position for power outages
• Wiring diagram for your stepper, showing the existing stepper with the new stepper

Power Requirement:
120/240V AC, Jumper Selectable 25 VA Max

Input Voltage Range:
24 to 300V AC or DC

Input:
All five (5) inputs are opto-isolated from each other. Typical labeling for inputs are: Step Down, Step Up, Bottom Reset, Middle Reset, and Top Reset.

Output:
Up to 63 positions and up to 8 rows (or banks). Each output has onboard contact suppression. For high inductive loads, a Diode-Resistor kit is supplied to enhance relay contact life.

Dimensions:
3" H, 5 1/4" W, 6 7/8" L for 16 floors Armor Stepper. Size will vary depending upon the number of floors and the number of banks.

Magnetic Button Replacement
P/N MB6

This card is used to change from the old type magnetic button car station, as were used by Otis and Westinghouse, to the new light-up type button car station. No controller wiring is required. Each card can accommodate 12 floors. Additional cards can be cascaded for additional floors.

Dimensions:
1" H, 2 1/2" W, 7" L

Current Sense Relay For Otis Touch-Tube Circuits
P/N CS1

This board was originally designed to replace the unavailable Ward Leonard Current Sensitive Relay that was used for this purpose. Other uses are for the updating of existing touch-button circuitry for "Fire Service Phase Two".

Dimensions:
3/4" H, 2" W, 2 5/8" L.

IP8300-Plus 2" Tape
P/N IP8300-2

The IP8300-Plus uses a hall effect sensor in conjunction with a magnetic target ‹ very much the same as a mechanical magnetic switch works with a target or vane.

The hall-effect sensors can be configured as:
• A single sensor - single output
• Two sensors in parallel - single output
• Two sensors in parallel - single output (as in Door Zone)

The outputs are usually a relay contact output with contact suppression but can be supplied with transistor open collector output.

A 2" wide tape is fastened at the top of the shaftway and is secured at the bottom of the shaftway with a spring-loaded bracket. The hall-effect sensors are housed in a floating head located on top of the elevator. The 2" tape is divided into three 1/2" rows with a 1/4" clearance on each edge of the tape. The sensors are polarity sensitive. Because of north and south seeking sensors, the 2" wide tape which has three (3) rows may in effect be expanded to six (6) rows.

The IP8300-Plus is used for new installation and also replaces existing installations. Some of the existing installations are Otis 140M and 6850 selector "pie plates" - also Westinghouse tape switches and inductor vane type.

Dimensions:
24" H, 3" W, 3" D.


IP8300-Plus 3" and 4" Tape

P/N IP8300-3; P/N IP 8300-4

The 3" wide and 4" wide tape units are the same as the 2" wide tape unit except it can facilitate five (5) rows for the 3" wide tape and seven (7) rows for the 4" wide tape.

Output Boards for the IP8300-Plus
P/N IP8300-R9, IP8300-R12

There are two types of boards available:
• 9 relay output board (P/N IP8300-R9)
• 12 relay output board (IP8300-R12)

The 9 relay output board has two separate commons, and the 12 relay output board has three separate commons. The outputs may be in any combination of normally open and normally closed contacts.

Power Requirement:
Both boards need 120VAC for power and have built-in contact suppression for the relay contact outputs.

Dimensions:
9 relay output: 2 1/2" H, 5 1/4" W, 6 3/4" L.
12 relay output: 2 1/2" H, 6 3/4" W, 6 3/4" L.

Digital Position Indicator Display with Direction Arrows
P/N REC1, REC2, REC3, XM1T1, SM1T2, XM1T3, XM1T-A

Features:
• 3 wire system for displays, can drive up to 48 displays
• Wide input range: 5 to 300 AC/DC. Standard, binary or special input logic.
• Small compact display design.
• All wiring done via pluggable terminals.
• Onboard digital displays.
• Alphanumeric displays with Up & Down direction arrows

Power Requirement:
120V AC, 80 VA maximum. Input Voltage Range: 5V to 300V AC/DC. Up to 63 floors.

Output:
3 wires for power to drive the displays. Up to 48 displays can be connected to one Encoder / Transmitter. No special wires are needed to drive the displays.

Dimensions:
1/2" Display with Arrows: 2" H, 1 3/8" W, 1 5/16" D.
1" Display with Arrows: 2 3/4" H, 2 3/16" W, 1 7/8" D.
2" Display with Arrows: 3 3/4" H, 4 5/16" W, 1 5/8" D.
Encoder / Transmitter: 3 3/4" H, 5 5/8" W, 9 1/4" L.


Stand-Alone Digital Position Indicator Display

Features:
• No transmitter is needed.
• Economical for low rise jobs.

Otis Touch Button Replacement
P/N 2040

The 2040 module can be used to replace the existing touch buttons in the elevator cab or the hallway. One 2040 module is needed per button in the hall stations. For example, one 2040 module for the up button and one for the down button. In the elevator cab, one module per floor is needed and in the case of two car stations, one module is needed but additional wires must be added to light up both car stations.

Dimensions:
1/2" H, 1 1/8" Sq.


Otis Touch Button Plus Replacement

P/N 2040-Plus

Features:
• Similar to our Patented 2040 module Touch Button replacement.
• Cross-firing of double gang pushbuttons for hall and car € Choice of any 24 Volt bulb (100 ma maximum). € 8 calls per board.

Dimensions:
3/4² H, 5² W, 8² L

Master Double Gong For Down Hall Lanterns
P/N MD

This board will allow you to update an existing controller with the handicap feature of a double gong for the down lantern. The board should be mounted in the motor room and connected to the existing hall lantern circuitry.

Dimensions:
0.75² H, 3.7² L, 2.4² W

Hall Lantern PI Board
P/N LPI

This board is a custom design for use in conjunction with a Microprocessor or a PLC controller.

Features:
• 4 binary coded Positions Inputs will provide 16 Elevator Position Indications.
• 2 Up and Down Lanterns Inputs with the above Positions Inputs will provide 16 Up Lanterns and 16 Down Lanterns.
• Triac outputs with onboard suppressions, designed for 120 VAC.
• On board digital position display.
• Cascade a second board to expand up to 32 floors with 32 PI¹s and Up/Down Lanterns.

Power Requirements:
24V, AC/DC

Input Voltage Range:
24V, AC/DC

Dimensions:
1² H, 5 3/4² W, 12²

Chime, Floor Passing
P/N FPC

Features:
Relay inputs to tolerate electrical noise on existing jobs. Single input pulse of any width or a continuous input will output the same length of sound for the Chime. Accepts Chime push button input to allow the chime to sound as the elevator is passing floors for one direction only.

Dimensions:
0.9² H, 3² W, 4.5² L

ANNUNCIATOR
P/N ANNU
A jewel lighted Annunciator is available for manually operated elevators. The Annunciator is available in several finishes: stainless steel, brass and aluminum. The resetting of calls maybe done manually or a system can be devised to automatically cancel calls with regard to direction and elevator position.

Custom Designs

Most of our products were designed because there was a real need for something better. As a result, a product was born. We can accommodate our customers, at no extra charge for design work, if your new design is exclusive, and if there is a promise of large quantities. If you do not plan on large quantities, we can arrive at an agreement that will be agreeable to all parties. In the event that your new design is not exclusive and the potential to sell it to others is great, we will not charge you for the design work. Again, the cost of any custom work we do is always negotiable.

Claddagh Electronics Ltd.
10-32 47th Rd., Long Island City, NY 11101
Tel: 718-784-0571 • Fax: 718-482-9471