Magnetek’s HPV 900 Series 2 AC Elevator Drive continues the tradition of high performance, high overload capacity and long-life reliability. It is designed for both new installations and modernization projects, and provides advanced closed-loop vector control for superior performance.

The HPV 900 Series 2 offers the fastest, easiest set-up adjustment; fewest callbacks; and the lowest total lifetime cost. This cost-effective AC drive gives you accurate acceleration and deceleration resulting in smooth ride quality for high- and moderate-speed applications. Magnetek’s proven technical expertise plus our superior customer service has placed us as the world’s leading source of innovative, built-to-last elevator drives.

Features / Benefits:

Designed and rated for the elevator applications

  • No oversizing needed
  • Designed with high overload capacity (250%)
  • An internal dynamic braking IGBT
  • Cooling fans run only when drive is in operation

Elevator application software and parameters

  • Offering the ultimate performance features
  • Unique elevator speed regulator
  • Parameters are in elevator industry terminology

Ease of set-up

  • No need for mechanical disconnect to tune critical motor parameters
  • Parameter upload/download software
  • Drive calculates elevator system inertia
  • Configurable I/O channels
  • Easy parameter changes via digital operator

Model Number for Ordering
(Manufacturer’s P/N )

HPV900 – 2 025 -2 E 1 – 01

HPV900 Series

  • Input Voltage:
    2 = 230V
    4 = 460/400V
  • Continuous Output Current:
    230V:
    025 = 25A
    031 = 31A
    041 = 41A
    052 = 52A
    075 = 75A
    088 = 88A
    098 = 98A
    460V:
    008 = 8A
    012 = 12A
    016 = 16A
    021 = 21A
    027 = 27A
    034 = 34A
    041 = 41A
    052 = 52A
    065 = 65A
    072 = 72A
    096 = 96A
    .
  • Series
    2 = Series 2
  • Operator:
    E = Elevator operator
    N = No Operator
  • Option #1:
    1
  • Software Program:
    01 = PM Software